Installation guide
set alarm
46 Chapter 2 Command Descriptions
set alarm
Devices
supported
Digi Connect EM, Digi Connect Wi-EM, Digi Connect ME, Digi Connect Wi-
ME, Digi Connect WAN, and Digi Connect RG. Setting alarms in GPIO
mode is not supported in the Digi Connect SP device.
Purpose Use this command to configure device alarms or display current alarm
settings. Device alarms are used to send emails or SNMP traps when
certain device events occur. These events include changes in GPIO
signals and data patterns in the serial stream. Up to 32 alarms can be
configured in Digi Connect devices.
Required
permissions
Permissions must be set to “set permissions s-alarm=read” to display
current alarm settings, and to “set permissions s-alarm=rw” to display
alarm settings and configure alarms. See "set permissions" on page 86 for
details on setting user permissions for commands.
Syntax Set alarms with general options (applies to all alarms)
set alarm [state={on|off} | mailserverip=ipaddress | from=string]
Set alarms with a range (set multiple alarms)
set alarm range={1-n}
[active={on|off}|to=string|cc=string|subject=string|
priority={normal|high}|mode={match|gpio}|
type={email|snmptrap|all}]
Set alarms in GPIO mode
set alarm range={1-n} mode=gpio
[pins=list_of_pins|highpins=list_of highpins|
lowpins=list of lowpins|pin{n}={high|low|ignore}|
trigger_interval=seconds|reminder={on|off}|
reminder_interval=seconds]
Note: n is the pin number.
Set alarms in match mode
set mode=match match=string
Display current alarm settings
set alarm [range={1-n}]