Specifications

18 DC-788 Operation Manual
32 Exit From Accumulation
Mode After 15 Second
Time Out
0: Allow (DEFAULT)
1: Inhibit
(SP_EA15)
Exit From Acculumation
Mode When Weight
Change
0: Allow (DEFAULT)
1: Inhibit
(SP_EAWC)
Quantity Accumulation
Without Removing
Weight
0: Allow (DEFAULT)
1: Inhibit
(SP_QARW)
Quantity Accumulation
Without Changing
Weight (for >= ±10e)
0: Allow (DEFAULT)
1: Inhibit
(SP_QACW)
33 Loadcell Sensitivity Selection mV/V (1st Scale)
0000: 0.95 ~ 1.09 (Default) 0100: 1,69 ~ 1.95 1000: 0.40 ~ 0.46 1100: 0.71 ~ 0.82
0001: 1.09 ~ 1.27 0101: 1.95 ~ 2.25 1001: 0.46 ~ 0.53 1101: 0.82 ~ 0.95
0010: 1.27 ~ 1.46 0110: 2.25 ~ 2.59 1010: 0.53 ~ 0.61
0011: 1.46 ~ 1.69 0111: 2.59 ~ 3.00 1011: 0.61 ~ 0.71
(SPSST)
34 Loadcell Sensitivity Selection mV/V (2nd Scale)
RLWS recommends a setting of 0000 for bench scales and 0011 for floor scales connected as a second scale.
0000: 0.95 ~ 1.09 0100: 1,69 ~ 1.95 1000: 0.40 ~ 0.46 1100: 0.71 ~ 0.82
0001: 1.09 ~ 1.27 0101: 1.95 ~ 2.25 1001: 0.46 ~ 0.53 1101: 0.82 ~ 0.95
0010: 1.27 ~ 1.46 0110: 2.25 ~ 2.59 1010: 0.53 ~ 0.61
0011: 1.46 ~ 1.69 (Default) 0111: 2.59 ~ 3.00 1011: 0.61 ~ 0.71
(SPSST1)
35 1st Scale Weight Unit
0: kg (DEFAULT)
1: g
(SP_GBASE1)
NOTE: Units for Scale 1
should be set to be the
same as the units on Scale
2 (See SPEC 35, Bit 2)
2nd Scale Weight Unit
0: kg (DEFAULT)
1: g
(SP_GBASE2)
NOTE: Units for Scale 2
should be set to be the
same as the units on Scale
1 (See SPEC 35, Bit 3)
Negative Weight
Display Mask Range
0: Minus Gross > 9e
1: Minus Gross >20e
(DEFAULT)
(SP_NMRG)
Not Used
0: (DEFAULT)
SPEC No. Bit 3 Bit 2 Bit 1 Bit 0
Table 3-2. DC-788 Weight and Measurement Specifications