Specifications
Configuration Settings 17
26 Weight Stability Conditions
00: Loose
01: Normal (DEFAULT)
10: Tight
11: Stringent
(SPWTATABC)
2nd Scale
Please note that the scale
switch is not activated until
the 2nd scale has been
calibrated.
0: Inhibit (DEFAULT)
1: Enable
(SP_SCALET)
IR Mode Protected by
Span Switch
0: No (DEFAULT)
1: Yes
(SP_SPSW)
27 Weight Unit Base
0: kg
1: lb (DEFAULT)
(SPBASE)
Type of Decimal Point
0: .(Standard) (DEFAULT)
1: ,(Europe)
(SP_DPF)
Negative Weight
Display Mask
0: Minus Gross > 9e
1: Minus Gross Weight
(DEFAULT)
(SP_NMASK)
Gross Mode
0: Allow
1: Inhibit (DEFAULT)
(SP_GROSSM)
Note: When the Gross
Mode is enabled, it disables
the ability to switch
between lb/kg or to switch
to APW because the lb/kg
key is used for the gross
mode. When Gross Mode
is enabled, the scale stays
in UW/1000 regardless of
how SPEC 3 is set.
28 Manual Tare
Cancellation
0: Allow (DEFAULT)
1: Inhibit
(SP_MTC)
Ta r e S ub t r a c t i o n
0: Allow (DEFAULT)
1: Inhibit
(SP_TS)
Ta r e A cc u mu l a t i o n
0: Allow (DEFAULT)
1: Inhbit
(SP_TA)
Auto Tare Clear When
Rezero
0: Allow
1: Inhibit (DEFAULT)
(SP_AUTOT)
29 Digital Tare
0: Allow
1: Inhibit (DEFAULT)
(SP_DT)
Accumulation When
Ta r e
0: Allow
1: Inhibit (DEFAULT)
(SP_ACCT)
Zero Tracking When
Ta r e
0: Allow (DEFAULT)
1: Inhibit
(SP_ZTT)
Weight Reset When
Tare
0: Allow (DEFAULT)
1: Inhibit
(SP_WR)
30 Ta r e A u t o C l e a r
0: Allow
1: Inhibit (DEFAULT)
(SP_TAUTO)
Unit Weight Auto Clear
0: Allow
1: Inhibit (DEFAULT)
(SP_UAUTO)
Auto Clear Condition
0: >=Gross 21e & >=Net 5e
1: >=Net 1e & Quantity Not
0 (DEFAULT)
(SP_AUTOCC)
Not Used
0: (DEFAULT)
31 Accumulation
0: 0: Allow (DEFAULT)
1: Inhibit
(SP_ACC)
Accumulation Number
Display
0: Allow (DEFAULT)
1: Inhibit
(SP_ANO)
WT Data
Synchronization (+ key
only)
0: Allow (DEFAULT)
1: Inhibit
(SP_WDS)
Accumulation Display
Style
0: “Total” (DEFAULT)
1: “Add”
(SP_ADS)
SPEC No. Bit 3 Bit 2 Bit 1 Bit 0
Table 3-2. DC-788 Weight and Measurement Specifications