Specifications

16 DC-788 Operation Manual
SPEC No. Bit 3 Bit 2 Bit 1 Bit 0
20 Version Display When
Power On
0: Allow (DEFAULT)
1: Inhibit
(SP_VER)
Selection of
Segment-Check Style
0: Fast (DEFAULT)
1: Standard
(SP_SEGCK)
Start Range
00: ±10% of Full Scale (DEFAULT)
01: ± 5% of Full Scale
10: ± 3% of Full Scale
11: ± 2% of Full Scale
(SPSRANGE)
21 Minimum Display (Scale 1)
00: 1
01: 2 (DEFAULT)
10: 5
11: 10
(SPMINID)
Minimum Display (Scale 2)
00: 1
01: 2
10: 5 (DEFAULT)
11: 10
SPMINID1)
22 Selection of Resolution (Scale 1)
0000: 1/2500
0001: 1/5000 (NTEP Setting)
0010: 1/10000 (DEFAULT)
0011: 1/15000
0100: 1/20000
0101: 1/25000
0110: 1/30000
0111: 1/12500
(SPRES)
23 Not Used
0: (DEFAULT)
Weight Decimal Point Position (Scale 1)
000: No Decimal Point
001: 1st Digit (0000.0)
010: 2nd Digit (000.00)
011: 3rd Digit (00.000)
100: 4th Digit (0.0000)
(SPWPT)
24 Selection of Resolution (Scale 2)
0000: 1/2500
0001: 1/5000 (NTEP Setting)
0010: 1/10000 (DEFAULT)
0011: 1/15000
0100: 1/20000
0101: 1/25000
0110: 1/30000
0111: 1/12500
(SPRES1)
25 Not Used
0: (DEFAULT)
Weight Decimal Point Position (Scale 2)
000: No Decimal Point
001: 1st Digit (0000.0) (DEFAULT)
010: 2nd Digit (000.00)
011: 3rd Digit (00.000)
100: 4th Digit (0.0000)
(SPWPT1)
Table 3-2. DC-788 Weight and Measurement Specifications