Specifications
Configuration Settings 15
3.1.2 Weight and Measurement Specifications (142 Settings)
To make changes to the Weight and Measurement Specifications, the span switch must be on. (For instructions
on how to turn the span switch on, see
Section 4.0.)
1. To configure customer specifications, press and hold the REZERO key and enter 142 using the numeric
keypad. The first SPC code is displayed.
The Weight display shows what specification you are in (in this case, SPC20). The Unit Weight display
shows how this specification is currently programmed (Bit 3 = 1; Bit 2 = 0; Bit 1 = 0, and Bit 0 = 0),
while the PCS display will show any changes you enter.
If this is the SPC that you want to modify, enter the new setting from the numeric keypad and press the *
PRINT key to enter the change into temporary memory and move to the next SPC code.
2. Use the + (Plus) and – (Minus) keys to scroll through the specifications until you find the one you want.
Then make your changes per the instructions in Step 1.
3. To change another SPC code before exiting, repeat Steps 1 and 2.
4. To save all the changed SPC settings currently in temporary memory and exit to the Weighing Mode,
press the TARE key.
14 Clear Unit Weight When
Swap Scale
0: No (DEFAULT)
1: Yes
(SP1_UC) (*V1.06)
Rezero When Swap Scale
0: No (DEFAULT)
1: Yes
(SP1_RZ) (*V.106)
Auto Scale Switching
0: No (DEFAULT)
1: Yes
(SP1_ASS) (*V1.07)
Zero Display
0: Display 0 With ‘/’
1: Display 0 Without ‘/’
(DEFAULT)
(SP1_DIS0) (*V1.10)
15 Display “MEM EXIST”
message reminding you
that there is an
accumulation in memory
0: No
1: Yes (DEFAULT)
(SP1_MEXIST) (V1.10)
Clear TARE Weight When
Swapping Scales
0: No (DEFAULT)
1: Yes
Scale Number in Text of
RS-232
0: No
1: Yes (DEFAULT)
Number of Setpoints
0: 2 Setpoints (Default)
1: 3 Setpoints
(SP1_SPN) (v1.10)
16 - 19 Not Used
SPEC No. Bit 3 Bit 2 Bit 1 Bit 0
Table 3-1. DC-788 (141) Settings