Specifications

10 DC-788 Operation Manual
2.5 Setting the Date
Without a power supply, the DC-788 will reset the time and date. For units that do have battery power, the time
and date can be supported for up to 20 days in the OFF status without any AC power supply. After 20 days the
unit will reset itself.
The procedure below can also be used to adjust the time when moving from Standard to Daylight Savings Time
or when the scale is moved to a new facility in a different time zone.
NOTE: SPC 04, Bits 3 and 2 - ORDER OF MONTH, DATE AND YEAR allows you to set the format for the date that you prefer
the scale to display. The default is 00: Month/Date/Year. To change these specifications, see
Section 3.1.2).
1. Press the MODE key twice until the display shows ProG.
2. Press the – (Minus) key to display the current time and date.
3. Press the – (Minus) key again.
4. Using the keyboard, enter the desired date i.e.: [0] [6] [0] [9] [0] [5] for June 9th, 2005.
5. Press the * PRINT key to store the date setting.
6. Using the keyboard, enter the time, i.e.: [1] [5] [0] [5]
7. Press the * PRINT key to store the time setting
8. Press the MODE key to exit the weighing mode.
2.6 Replacement Parts
The following list contains the part numbers and descriptions of replacement parts available for the DC-788
counting scale.
RLWS Part Number Description
88933 Battery Pack, 6 V, 5.0AH lead acid
89994 Keysheet, 16 keys, DC-788
89997 Keysheet, 8 keys, DC-788
89999 Keyboard
90152 Mainboard for DC-788
90153 Loadcell, 2 lb
90154 Loadcell, 10 lbs
90155 Loadcell, 20 lbs
90156 Loadcell, 50 lbs
90157 Loadcell, 100 lbs
90188 Top c ov er
90160 Support platter
90171 Platter cover, 10 lb to 100 lb
65956 Platter cover, 2 lb
Table 2-1. DC-788 Replacement Parts