Specifications

48 DC-200/300 Operation Manual
8. Repeat Step 7 above until you are done adding or subtracting all the bins or boxes of this item.
9. Press the
* REPRINT key to add or subtract the quantity shown on the display to the amount already stored
under the item code memory. The display will briefly say
Please Wait... then return to normal.
Note: If SPEC 31 - PC/PRN Output is set to 2: By +/-/PRINT KEY, a label will print when you hit the REPRINT key showing the
count for this particular container in the default label format or the label format pre-programmed to be associated with this
particular item.
10. To view the updated inventory total, press the SHIFT DOWN key followed by the E key (for INVENT). The
second line of the scale display will show the updated inventory quantity. To exit the inventory display,
press the
CLEAR key.
11. Remove the parts from the platter and press the
CLEAR key to exit this item code. The In or Out
annunicator will also light.
5.11.6 Delete Item Memory
Deletion of an item code with all of its associated information (unit weight, tare weight, label format, part name,
part number, lot number, location, inventory quantity, threshold, setpoints, and address number) can only be
done from the item programming mode.