Specifications
44 DC-200/300 Operation Manual
Negative Counting - Total Removed Displayed at the End
With this procedure you can count accurately out of a full container for kiting, shipping, etc.without having to
know the tare weight of the container.
1. Place a full container on the scale and press
TARE.
2. Remove a 10 piece sample from the container and press
PIECES. After the unit weight has been
calculated, return the 10 piece sample to the container.
3. Remove the number of pieces you need for kiting, shipping, etc. The amount removed will be displayed.
If you need a label for each kit or container, press the
+ key after removing each batch of pieces. Then
press the
TARE key.
4. When you have removed the last batch of pieces, press the
* REPRINT key to show the total number of
pieces you have counted out of the full container.
Clearing Accumulated Data
To clear accumulated data, press the *REPRINT key.
5.10.3 Sample, Count and Print a Label
Note: For this function to be used on the DC-200, an external printer must be connected to the scale.
1. Press the REZERO key to zero the weight display.
2. Place the empty bin on the scale and press the
TARE key.
3. Place a 10 piece sample of the item in the bin and press the
PIECES key. (for maximum accuracy, count
the 10 piece sample into your hand and then add the entire sample to the bin at one time, instead of
adding them one or two pieces at a time). If 10 pieces are not enough for the scale to get an accurate
sample, the scale will prompt you to add a specific additional number of pieces. Add these pieces and
press the
PIECES key again.
4. Add the remaining pieces to be counted into the bin.
5. Press the
* REPRINT key. The scale will print a label in the default label format.
5.10.4 Scan ID Bar Code, Count, and Print a Label
Note: For this function to be used on the DC-200, an external printer must be connected to the scale.
1. Enter the ID code by scanning the ID bar code.
2. Press the
REZERO key to zero the weight display.
3. Place the container of the product on the scale platter.
4. Press the
* REPRINT key. The scale will print a label in the default label format.
5. To print a label in the default label format showing the total, press the
* REPRINT key. This will also clear
the accumulation register. The memory annunciator
S is no longer illuminated.