Specifications

20 DC-200/300 Operation Manual
3.1.2 Weight and Measurement Specification (142 Settings)
1. Press and hold the REZERO key and enter 142 using the numeric keypad. SP600 appears in weight display
and its current setting (ex.
2>2: LB) appearing in the second line. If this is the SPEC that you want to
modify, press the
>> or << keys to scroll through the possible settings. When the setting you want to store
is displayed, press the + (plus) key to enter the change into temporary memory and move to the next
SPEC code.
2. If you want to modify a SPEC other than SPEC 600 and you know the number of that SPEC code, enter
the number of the SPEC code on the numeric keypad and press the
*REPRINT key. Otherwise, you can
use the + (plus) and (minus) keys to scroll through the specifications until you find the one you want.
Then make your changes per the instructions in Step 1.
3. To change another SPEC code before exiting, repeat Steps 1 and 2.
4. To save all the changed SPEC settings currently in temporary memory and exit to the Operation Mode,
press the
CODE key. To exit to the Operation Mode without saving the changes, press the TARE key.
5. Power down scale using the power switch on the back of the bottom of the scale, not the
ON/OFF key on
the keyboard.
6. Power scale on to re-initialize the new specification settings.
73 Print Barcode
This option allows you to print barcodes on labels with all headers printed, with no headers printed, or
with all headers except the header for the Quantity barcode.
0: With Header (DEFAULT)
1: All Without Header
2: Quantity Without Header
74 Overwrite Unit Weight
Allows you to protect the Unit Weight so that it cannot be overwritten by the operator.
0: No (DEFAULT)
1: Yes (If Unit Weight = 0)
SPEC Description
Table 3-1. DC-200/300 (141) Settings
Spec Description
600
Scale Unit Specification
0: Gram
1: Kg
2: Lb (DEFAULT)
601
Display Resolution
0: 1/10000 (DEFAULT)
1: 1/5000
2: 1/2500)
602
Internal Count
0: 500,000
1: 1,000,000 (DEFAULT)
603
Minimum Display (Increment) for Scale A
0: 2 (DEFAULT)
1: 1
2: 5
3: 10
Table 3-2. DC-200/300 (142) Settings