Specifications

Configuration Settings 15
09 Display Accuracy Unit Weight Calculation During Recomputing
0: No (DEFAULT)
1: Yes
10 Set Point Buzzer
0: Buzzer on (DEFAULT)
1: Buzzer off
11 Clear All Input Key in One Touch
0: Yes
1: No (DEFAULT)
12 Keep Lot Number in Registration (Operation) Mode
0: Allow (DEFAULT)
1: Inhibit
13 Job Sequence
0: Disable (DEFAULT)
1: Enable
14 Auto Exit From Add Mode
0: No
1: Yes (DEFAULT)
15 SIO Select Job
Defines what the primary or standard input/output port on the scale is connecting to.
0: No operation (DEFAULT)
1: Not Used
2: PC
3: Printer
4: Bar Code Scanner
16 RS-232C Baud Rate (SIO - Standard Input/Output Port)
0: 1200 baud
1: 2400 baud
2: 4800 baud
3: 9600 baud (DEFAULT)
4: 19200 baud
5: 38400 baud
17 RS-232C Data Length (SIO - Standard Input/Output Port)
0: 7 bits
1: 8 bits (DEFAULT)
18 RS-232C Parity Bit (SIO - Standard Input/Output Port)
0: None (DEFAULT)
1: Odd
2: Even
19 RS-232C Stop Bit (SIO - Standard Input/Output Port)
0: 1 bit (DEFAULT)
1: 2 bits
20 RS-232 Option Card
0: Not connected (DEFAULT)
1: Not Used
2: Not Used
3: Printer/PC
4: PC/Printer
5: Not Used
6: Not Used
SPEC Description
Table 3-1. DC-200/300 (141) Settings