Specifications
134 DC-200/300 Operation Manual
12.4.6 Programming the QSC-6000 Plus Quickscan RS232C Scanner
If you are using the Quickscan RS232C barcode scanner sold by Rice Lake Weighing Systems for DIGI scales,
scan the following bar codes to set the scanner for proper communication with the DC-200/300.
1. Set to RS232 default values and enable RS232
interface
Warning: use this barcode with caution because it will
clear any features you may have programmed since the
scanner’s installation and reset them all to the defaults.
2. Program communication settings
Parity = Even
Stop Bits = 1
Data Bits = 7
Set
Even Parity
One
Stop Bit
7 Data
Bits
End