Specifications

6.7. CONNECTOR MATRIX
6.7.1.1. DC-90 Connector Matrix
SX-1 Remote P/F DIN #1 DIN #2 “D” Set Point
SX-1
Platforms
Remote
Platforms
Bar Code
DIN #1 Din #2 “D” Set Point
Single SX
Platform
Any Remote
2
nd
Platform
Laser/Pen
Spec 14 & 15
Force Balance
Spec 13
PC
Spec13
Dual SX
Platform
Any Remote
3
rd
Platform
BCP-30
Spec 10 & 11
BCP-30
Spec 13
Single SX & Any
2
nd
P/F
Any Remote
3
rd
Platform
PC
Spec 8 & 9
Force Balance
Spec 13
SX Provides
AC or Battery
Power
Single Non SX
P/F
Any Remote
2
nd
Platform
Requires PS-100 A/C Adapter
Two Non SX
Platforms
Any Remote
3
rd
Platform
Requires PS-100 A/C Adapter And “Y” Cable
NOTE: WHEN THE DC-190 CONSOLE IS BENG USED WITH A PLATFORM OTHER THAN AN SX PLATFORM
THE PS-100 A/C ADAPTER IS REQUIRED
6.7.1.2. Comm Cables
!!
!!
ALL DC-190 counting scales have hardware handshaking lines for
RTS /CTS on DIN #2 and the 9 PIN “D” sub connectors. This is for use with certain printers
listed in this manual. For devices that do not require this type of handshaking, jump the
RTS /CTS lines on the scale side of the cable.
[8 PIN] DIN # 1 & # 2 9 PIN “D” Female Setpoint Output
pin 1 DTR DTR pin 1 DCD MINI DIN 8 PIN
pin 2 S . GND S . GND pin 2 RD pin 1 SP-1
pin 3 DS R DS R pin 3SD pin 2 SP-2
pin 4 RXD RXD pin 4 DTR pin 3 SP-3
pin 5 TXD TXD pin 5SG pin 4 SP-4
pin 6 CTS CTS pin 6 DS R pin 5 SP-5
pin 7 RTS RTS pin 7RTS pin 6 SP-6
pin 8 vcc (5V) n/c pin 8CTS pin 7+ 24V
pin 9 Ri pin 8 GND
6.7.1.3. Remote Platform Wiring
DIGI REMOTE PLATF O R M WIRING
PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8
(+) EXCITATION (
)
EXCITATION
SHIELD (+) SIGNAL (
) SIGNAL GROUND