DC-190 RS-232 specification (continued)
(C) DATA
ID Code: Parts code is only sent when a ID Code is called during the counting mode.
The maximum is 16 characters. If the ID code is less than 16 characters, then the rest
of the data will be filled with space (20H).
Ex. Parts code = 12
Header <------------------------- DATA ----------------------------------------->
3 12SP SP SPSPSPSPSP SP SPSPCR
Set Points : Set Point data is only sent when a ID Code is called during the counting mode.
There are 6 set point data to be sent : Set Point 1 (F or G) , Set Point 2 (H).,
Set Point 3(a) , Set Point 4(b), Set Point 5( c) and Set Point 6 (d).
Set Point 1 (F) Weight : Variable length, Max 5 digits and 1 decimal point.
or (G) Quantity : Variable length, Max 6 digits.
(Note : Only one of “F” (set 1 weight) or “G” (set 1 quantity) is sent.)
Set Point 2 to 6 (H, a, b, c, d)
Percentage : Variable length, Max 5 digits and 1 decimal point.
or Lower Weight : Variable length, Max 5 digits and 1 decimal point.
or Lower Quantity : Variable length, Max 7 digits.
4 combinations of set point 1 and set point 2 can be sent as follows:
SET 1 SET 2,3,4,5,6
* Quantity & Percentage
* Upper Quantity & Lower Quantity
* Weight & Percentage
* Upper Weight & Lower Weight
Please Note: Set Point 2 to 6 must either increase or decrease .
The decimal point for weight must be correct.
Gross Weight : Variable length, Max 5 digits and 1 decimal point.
Net Weight : Variable length, Max 5 digits and 1 decimal point.
Unit Weight : Variable length, Max 5 digits and 1 decimal point.
Tare Weight : Variable length, Max 5 digits and 1 decimal point.
Quantity : Variable length, Max 7 digits.
Total Quantity : Variable length, Max 7 digits sent when PRINT key is depressed.
Note : Only one of “2” (Quantity) or “I” (Total Quantity) is sent at a time.