Specifications
6.5. DC-190 Specification List ver.3.37 (continued)
Spec No. Bit 3 Bit 2 Bit 1 Bit 0
30 Load Cell Sensitivities Selection (mV/V) (Scale 1)
Spc Min Max Spc Min Max Spc Min Max Spc Min Max
0000
0001
0010
0011
3.46
3.00
2.59
2.25
4.00
3.46
3.00
2.59
0100
0101
0110
0111
1.95
1.69
1.46
1.27
2.25
1.95
1.69
1.46
1000
1001
1010
1011
1.09
0.95
0.82
0.71
1.27
1.09
0.95
0.82
1100
1101
1110
1111
0.61
0.53
0.46
0.40
0.71
0.91
0.53
0.46
31 Load Cell Sensitivities Selection (mV/V) (Scale 2)
Spc Min Max Spc Min Max Spc Min Max Spc Min Max
0000
0001
0010
0011
3.46
3.00
2.59
2.25
4.00
3.46
3.00
2.59
0100
0101
0110
0111
1.95
1.69
1.46
1.27
2.25
1.95
1.69
1.46
1000
1001
1010
1011
1.09
0.95
0.82
0.71
1.27
1.09
0.95
0.82
1100
1101
1110
1111
0.61
0.53
0.46
0.40
0.71
0.91
0.53
0.46
32
1 0 1 0
Calibration Mode
protected by Span
Switch
0 : Yes 1 : No
Battery Low
Lamp
0: Yes
1: No
Auto Exit from
Add Mode
0 : No
1 : Yes
External Load Cell (Scale 3)
0: No
1: Yes
33
0 _ _ _
Over Weight Mask
at
0 : +1d
1 : +9d
Weight Decimal Point Position (Scale 3)
000 : 00000 011 : 00.000
001 : 0000.0 100 : 0.0000
010 : 000.00
34
0 0 0 0
Not used (For Scale 1)
0 :For Std / Normal Load
Cell
1: For abnormal load cell
with too large offset.
A/D Board (Scale 1)
00 : Normal
01 : Prevent from Small vibration/ fast change in display
10 : Prevent from Medium vibration
11 : Prevent from Large slow change in display
35
0 0 0 0
Not used (For Scale 2)
0 :For Std / Normal Load
Cell
1: For abnormal load cell
with too large offset.
A/D Board (For Scale 2)
00 : Normal
01 : Prevent from Small vibration/ fast change in display
10 : Prevent from Medium vibration
11 : Prevent from Large slow change in display
36
_ _ 0 0
Minimum Display ( Scale 3)
00 : 2 10 : 5
01 : 1 11 : 10
A/D Board (For Scale 3)
00 : Normal
01 : Prevent from Small vibration/ fast change in display
10 : Prevent from Medium vibration
11 : Prevent from Large slow change in display
37 Load Cell Sensitivities Selection (mV/V) (Scale 3)
Spc Min Max Spc Min Max Spc Min Max Spc Min Max
1 0 0 1
0000
0001
0010
0011
3.46
3.00
2.59
2.25
4.00
3.46
3.00
2.59
0100
0101
0110
0111
1.95
1.69
1.46
1.27
2.25
1.95
1.69
1.46
1000
1001
1010
1011
1.09
0.95
0.82
0.71
1.27
1.09
0.95
0.82
1100
1101
1110
1111
0.61
0.53
0.46
0.40
0.71
0.91
0.53
0.46
38
0 0 1 0
(For Scale 3)
0 :For Std / Normal
Load Cell
1: For load cell with
large offset
Digital Tare When
Loaded
0: Allow
1:Not Allow
INTERNAL COUNT
0: 500,000
1: 1,000,000
Stability Check When
Changing Scale
0 : Yes
1 : No
39 Set spec to “0” “0” “1” “0”