Specifications
5.2.4. Set Point Programming by Upper and Lower Limit of Weight:
Set Point 1 : Weight (See Note Below) Set Point 2 : Weight (See Note Below)
Set bit 0 and 1 of Spec 7 to 11
1 Display in the weighing mode
2 Press the [MODE] key to go into the programming mode.
3 Press [++
++
] key to go into Set Point Programming Mode.
4 Enter the upper weight value for Set Point 1 using the [Numeric] keys depending on the capacity o
f
the scale. Example: type [3][.][0][0][0][0] Please see the note below.
5 Press the [++
++
] key to program Set Point 2.
6 Enter the lower weight value for Set Point 2 using [Numeric] keys. Example: typ
e
[2][.][0][0][0][0]Please see the note below.
7 Pressing the [++
++
] key exits from the Set Point Programming mode, but remains in the Programmin
g
mode.
8 Pressing the [MODE] key exits from Programming mode and returns to Weighing mode.
Note : Set Point 1 : Must be a valid weight value up to the capacity of the scale.
Set Point 2 : Weight value up to the capacity of the scale, but Set Point 2 value must be less than Set
Point 1 value.
5.2.5. Set Point Programming by Weight or by Quantity:
Set Point Weight (See Note Below) Set bit 0 and 1 of Spec 7 to 11
Set Point Quantity (See Note Below) Set bit 0 and 1 of Spec 7 to 10
1 Display in the weighing mode
2 Press the [MODE] key to go into the programming mode.
3 Press [++
++
] key to go into Set Point Programming Mode.
4 Enter the Weight value for Set Point 1 using the [Numeric] keys depending on the capacity of th
e
scale. Example: type [2][.][0][0][0][0] Please see the note below.
5 Press the [++
++
] key to program Set Point 2.
6 Enter the weight value for Set Point 2 using [Numeric] keys. Example: typ
e
[3][.][0][0][0][0]Please see the note below.
7 Press the [++
++
] key to program setpoint 3 through 6 or exits from the Set Point Programmin
g
mode(depends on spec 18), but remains in the Programming mode.
8 Pressing the [MODE] key exits from Programming mode and returns to Weighing mode.
Note: The DC-190 can program up to six setpoints by repeating the process 3 through 6. Spec
18 bit 0-1-2 determine the number of setpoints. The six setpoints are TTL Output for Quantity
or Weight. These six setpoints may be programmed 1
through 6 low to high or 1 through 6 high
to low.