5.1.3. Example 3 : Program Part No, Part Name Using T-C For Alpha/Numeric via DC190 keypad And Set Points
12 Input 2 Digit Teraoka Code
13 Enter Part No: example [01] [02] [03] [00] [31] [32] [33] = ABC 123
14 Press [++
++
] or [
] to shift to right or left position
15 Press [
] key to store Part No
16 Press [CODE] key for Part Name
17 Input 2 Digit Teraoka Code
18 Enter Part Name: example [01] [02] [03] [00] [31] [32] [33] = ABC 123
19 Press [++
++
] or [
] to shift to right or left position
20 Press [CODE] key to store Part Name
21 Press [++
++
] key to check set point 1
22 Press [++
++
] key to check set point 2
23 Press [++
++
] key to Store the set Point
24 Press [""
""
] key to Store the Item into memory
5.2. Set Point Programming :
5.2.1. Set Point Programming by Quantity %
Set Point 1 : Quantity (See Note Below), Set Point 2 : % Quantity (See Note Below)
Set bit 0 and 1 of Spec 7 to 00
1 Display in the weighing mode
2Press the [MODE] key to go into the programming mode.
3 Press [++
++
] key to go into Set Point Programming Mode.
4 Enter the Quantity for Set Point 1 using the [Numeric] keys. Example type [1][0][0][0][0]
5 Press [++
++
] key to go to Set Point 2.
6
Enter the new Set Point 2 value using the [Numeric] keys. Example type [7][5] (See
! below)
7 Pressing the [++
++
] key exits from the Set Point Programming mode, but remains in the Programming
mode.
8 Pressing the [MODE] key exits from Programming mode and returns to Weighing mode.
NOTE: Using the [CLEAR] key clears the key entry.
! Note : Set Point 1 : Must be a quantity value up to 999999.
Set Point 2 : Percentage value up to 999%, but set according to Set Point 1 value.
Ex: Suppose Set Point 1=999999, Set Point 2 cannot be set more than 100%.