Specifications

4.3.2. Unit Weight Operation by Key Entry : This following procedure is used if the unit weight is
already known.
1 Display in the weighing mode
2 Enter the known Unit Weight using the keyboard. [2][.][8][7]
3Press the [UNIT WEIGHT] key to enter the unit weight.
4Place 2 lb weight on the platter. The scale displays the quantity for the weight placed on the
platter. (A 2 lb. weight is used as an example only.)
4.4. Accumulation Operation When Spec 32 bit 1, Default Setting, (Auto Exit when Accumulation) is
enabled, The Scale will automatically go back to weight mode after the Accumulation.
1 After Unit Weight entry. (See 4.3)
2 Press the [++
++
] key. The Total is displayed in the Quantity Display.
3 The memory lamp will glow. After a moment the scale will resume operation mode.
4 Put 1.0lb on the platter
5 Press the [++
++
] key. The Total is displayed in the Quantity Display.
6 The memory lamp will glow. After a moment the scale will resume operation mode.
7 The previous total of 25 and the present quantity of 15 are added and the Total Of 40 is
displayed in the Quantity Display.
8 The memory lamp will glow. After a moment the scale will resume operation mode.
9 Pressing the [++
++
] key makes the total 15 + 40 = 55, displayed in the Quantity Display.