Specifications
48
39. 2.5 SET POINT OUTPUT
PROGRAMMING
You can program an INDIVIDUAL set point for each ID Code being weighed and
counted or set the GENERAL set point value for all items.
1. Enter PRG mode PRG: ID CODE
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8
2. Select Set Point value with PRG: SET POINT
[UNIT WEIGHT →
→→
→] key.
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8
3. Press [∗
∗∗
∗ ENTER] key.
S.P= 0/ 0
∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇
. . . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R I M I O 1 2 3 4 5 6 7 8
4. Enter Set point value 1 and press [ F ] key. S.P= 5 0 0/ 0
I.e.) Set point 1 = 5,000 Set point 2=3,000
∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇
. . . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R I M I O 1 2 3 4 5 6 7 8
5. Move the cursor to right by pressing S.P= 5 0 0 0/ 0
[UNIT WEIGHT→
→→
→] key.
∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇
. . . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R I M I O 1 2 3 4 5 6 7 8
6. Enter Set point value 2. S.P= 5 0 0 0/ 3 0 0 0
∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇
. . . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R I M I O 1 2 3 4 5 6 7 8
7. Press [F] key.
S.P= 5 0 0 0/ 3 0 0 0
∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇ ∇
∇∇
∇
. . . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R I M I O 1 2 3 4 5 6 7 8
8. Press [∗
∗∗
∗ ENTER] key.
PRG: SET POINT
. . . . . . . . . . . . . . . . . . . .
Z S N K 1 2 3 I R M I O 1 2 3 4 5 6 7 8
Note)
"
You can change the combination of set points functions in Misc Spec 00-01 in
Maintenance mode.