Specifications
17
11. OVERVIEW OF SET POINT OUTPUT
Two target values can be programmed for each ID CODE in Memory. A beep sounds to
indicate when the target value is reached. (SET1/SET2.)
The combination of SET1 and SET2 can be selected as follows in Maintenance mode.
COMBINATION SET POINT 1 SET POINT 2
QUANTITY & PERCENTAGE QUANTITY % OF SET POINT 1
QUANTITY & PERCENTAGE ( TO STOP QUANTITY % OF SET POINT 1
WEIGHT & PERCENTAGE WEIGHT(g) % OF SET POINT 1
UPPER LIMIT & LOWER LIMIT OF WEIGHT UPPER LIMIT LOWER LIMIT
UPPER LIMIT & LOWER LIMIT OF QUANTITY UPPER LIMIT LOWER LIMIT
I.E.: COMBINATION = QUANTITY (25,000 PCS.) & 80 %
INTERMITTENT CONTINUOUS
SET POINT 2 SET POINT 1
0 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 80 % 25,000 PCS
20,000 PCS TOTAL
* When the weight value is a equal to (or over) the target SET1, intermittent buzzer
sounds. When the weight value is a equal to (or over) the target SET2, buzzer change
to continuous.