Specifications
128
13. MANUAL PROGRAMMING OPERATION
1. Enter Maintenance mode and select MODEM
with
[ TARE←
←←
←] or [UNIT WEIGHT→
→→
→] keys
MTN : MODEM COMM.
. . . . . . . . . . . . . . . . . .
. .
Z S T K 1 2 3 I R M I O 1 2 3 4 5 6
7 8
2. Press [∗
∗∗
∗/
//
/ENTER] key
MDM = MODEM (MANUAL)
. . . . . . . . . . . . . . . . . .
. .
Z S T K 1 2 3 I R M I O 1 2 3 4 5 6 7
8
3. Press [∗
∗∗
∗/
//
/ENTER] key.
MAN : ENTER TELEPHONE #
* [R] key is used for re-dial
• • • • • • • • • • • • • • • • • • • •
Z S T K 1 2 3 I R M I O 1 2 3 4 5 6 7
8
4. Enter telephone number then press [∗
∗∗
∗/
//
/ENTER]
key.
MAN : MODEM (SEND)
• • • • • • • • • • • • • • • • • • • •
Z S T K 1 2 3 I R M I O 1 2 3 4 5 6 7
8
5. Select Receive/ Send / End with [TARE←
←←
←] or
[UNIT WEIGHT→
→→
→] then press [∗
∗∗
∗/
//
/ENTER] key
SEN = SPEC CODES ? Y / N
Ex) send
• • • • • • • • • • • • • • • • • • • •
Z S T K 1 2 3 I R M I O 1 2 3 4 5 6 7
8
6. Select if you send SPEC data with [Y] = yes or
[N] = No
SEN = PRINT FORMAT ? Y / N
• • • • • • • • • • • • • • • • • • • •
Z S T K 1 2 3 I R M I O 1 2 3 4 5 6 7
8
7. Select if you send PRINT FORMAT data with
[Y]= Yes, [N] = No
SEN = AUTO JOB ? Y / N
• • • • • • • • • • • • • • • • • • • •
Z S T K 1 2 3 I R M I O 1 2 3 4 5 6 7
8