Specifications
Configuration Settings 15
3. To change another SPEC code before exiting, repeat Steps 1 and 2.
4. To save all the changed SPEC settings currently in temporary
memory and exit to the Weighing Mode,
press the TARE key.
5. Turn off Power and restart the scale.
SPEC No. Bit 3 Bit 2 Bit 1 Bit 0
20 Version Display When
Po
wer On
0: Allow (DEFAULT)
1: Inhibit
Selection of
Segment-C
heck Style
0: Fast (DEFAULT)
1: Standard
Start Range
00: ±10% of Full Scale (DEFAULT)
01: ± 5% of Full Scale
10: ± 3% of Full Scale
11: ± 2% of Full Scale
21 Wight Stability Condition
00: Loose
01: Nornal (DEFAULT)
10: Tight
11: Stringent
IR Mode Protected by
Span Sw
itch
0: No (DEFAULT)
1: Yes
Password Setting
0: Allow
1: Inhibit (DEFAULT)
22 Decimal Point Position on Weight Display
00: No Decimal Point
01: 2nd Digit (0000.0)
10: 3rd Digit (000.00) (DEFAULT 50 lb)
11: 4h Digit (00.000) (DEFAULT for 6 lb, 25 lb)
Minimum Display
00: 1 ((DEFAULT 6 lb)
01: 2
10: 5 (DEFAULT 25 lb)
11: 10 (DEFAULT 50 lb)
23 Weight Single Interval
or Multi-Interval
0: Single Interval (DEFAULT
6 lb)
1: Multi-Interval (DEFAULT
25 lb, 50
lb)
Selection of Resolution
000: 1/2,500
001: 1/5,000 (DEFAULT 25 lb, 50 lb)
010: 1/10,000
011: Not Used
100: 1/3,000 (DEFAULT 6 lb)
101: 1/6,000
110: 1/7,500
111: Not Used
24 Negative Weight
Disp
lay Mask
0: Minus gross > 9e
1: Minus gross weight
(DE
FAULT)
Gross Mode
0: Allow (DEFAULT)
1: Inhibit
PLU Tare
0: Allow (DEFAULT)
1: Inhibit
Tare Ra nge
0: 50% of full scale
(DEF
AULT)
1: 100% of full scale
25 Manual Tare
Ca
ncellation
0: Allow
1: Inhibit
Ta re Subtr a c t i o n
0: Allow
1: Inhibit
Tare Accumulation
0: Allow
1: Inhibit
Auto Tare Clear When
Re
-Zero
0: Allow
1: Inhibit
26 Digital Tare
0: Allow (DEFAULT)
1: Tare
Accumulation When Tare
0: Allow (DEFAULT)
1: Inhibit
Zero Tracking When
Ta
re
0: Allow (DEFAULT)
1: Inhibit
Weight Reset When
Ta
re
0: Allow (DEFAULT)
1: Inhibit
Table 3-2. DC-782 Weight and Measurement Specifications