International Scale User Manual
22 DC-190 Ultra Count Installation Manual
27 0100 Comma Display
0:No
1:Yes
Keypad Entry of Tare
0: No
1: Yes
Tare Range
00: 100% FS 01: 50% FS
10: 5% FS 11: Not used
28 0000 Auto Tare Clear when 
Rezeroed
0: No
1: Yes (REZERO 
clears tare value)
Automatic Unit Weight Clear Condition
00: Over net 5d and gross 21d, weight stable
01: Greater than or equal to net 1d, weight stable
10: Greater than or equal to net 1d, quantity > 0, 
weight stable
Automatic Unit Weight 
Clear
0: No
1: Yes
29 0000 Digital Tare Rounding
0:Tare exactly
1:Round to nearest 
increment
Tare Value Exchange 
with TARE key
0: Yes (allow tare 
addition/subtraction)
1: No
Tare Addition
0:Yes (new tare weight 
added to existing tare)
1:No
Tare Subtraction
0: Yes (new tare weight 
subtracted from 
existing tare)
1: No
30 none Load Cell Sensitivity Selection (mV/V)—PORT 1, Scale 1
Load cell sensitivity is automatically set at calibration. Manual adjustments can be made to reduce noise.
Spec
Min Max
0000: 3.46 4.00
0001: 3.00 3.46
0010: 2.59 3.00
0011: 2.25 2.59
Spec
Min Max
0100: 1.95 2.25
0101: 1.69 1.95
0110: 1.46 1.69
0111: 1.27 1.46
Spec
Min Max
1000: 1.09 1.27
1001: 0.95 1.09
1010: 0.82 0.95
1011: 0.71 0.82
Spec
Min Max
1100: 0.61 0.71
1101: 0.53 0.91
1110: 0.46 0.53
1111: 0.40 0.46
31 none Load Cell Sensitivity Selection (mV/V)—PORT 1, Scale 2
Load cell sensitivity is automatically set at calibration. Manual adjustments can be made to reduce noise.
Spec
Min Max
0000: 3.46 4.00
0001: 3.00 3.46
0010: 2.59 3.00
0011: 2.25 2.59
Spec
Min Max
0100: 1.95 2.25
0101: 1.69 1.95
0110: 1.46 1.69
0111: 1.27 1.46
Spec
Min Max
1000: 1.09 1.27
1001: 0.95 1.09
1010: 0.82 0.95
1011: 0.71 0.82
Spec
Min Max
1100: 0.61 0.71
1101: 0.53 0.91
1110: 0.46 0.53
1111: 0.40 0.46
32 1010 Calibration Mode 
Protected by Span 
Switch
0:Yes (span switch 
must be pressed 
before calibration)
1:No
Low Battery 
Annunciator Enabled
0: Yes
1: No
Auto Exit from Part 
Accumulation and 
Reduction Mode
0:No (must press 
CLEAR to perform 
another accumulation)
1:Yes (exits to counting 
mode after three 
seconds)
Scale Connected to 
PORT 2
0: No
1: Yes
CAUTION: If you are not 
connecting a scale to this 
connector, select 0. 
Selecting 1 can damage 
the console’s electronic 
components. 
33 0___ Over Weight Mask at: 
0:+1d
1:+9d
Weight Decimal Point Position (PORT 2, Scale 2 or 3)
MUST BE SET PRIOR TO CALIBRATION!
000: 00000 011: 00.000
001: 0000.0 100: 0.0000
010: 000.00 101: 0.00000
34 0000 Not used A/D Output (PORT 1, 
Scale 1)
0: For std/normal load 
cell (≤ 18 mV)
1: For abnormal load 
cell with too large 
offset (> 18mV)
A/D Filtering (PORT 1, Scale 1)
00: Normal
01: Protect from small vibration/fast change in 
display
10: Protect from medium vibration
11: Protect from large vibration, slow change in 
display
SPEC Default Bit 3 Bit 2 Bit 1 Bit 0
Table 4-2. DC-190 142 Settings (Continued)