User`s guide

Hardware specifications
226
ConnectPort X4 H specifications
Specification Value
Environmental Ambient
temperature
-40F to 140F (-40C to +60C)
Relative humidity Relative humidity not to exceed 95% non-condensing over the
temperature range of from 4C to 45C. Above 45C, constant absolute
humidity shall be maintained.
Storage and
transport
temperature
-40F to 185F (-40C to 85C)
Altitude 6560 feet (2000 meters)
Ethernet isolation 1500VAC min per IEEE802.3/ANSI X3.263
IP rating IP66
Power
requirements
DC power input
Voltage input: 6-30VDC
Power consumption: Idle: 1.5W Max: 10.4W
Connector: 2.35mm x 5.7mm, locking barrel, center pin positive.
AC power supply
Certifications: CE/UL /c-UL Listed ITE (LPS) or Class II power
supply
Input voltage: 100 VAC to 240 VAC
Input frequency: 47-63 Hz
Max input watts: 25W max
Power: US power cord or European cord option
Dimensions Length 9.5 in (24.13 cm)
Width 6.25 in (15.88 cm)
Depth 3.5 in (8.89 cm)
Weight 3.2 pounds (1.45 kg)
Mounting
orientation
The ConnectPort X4 H should be mounted to a flat, secure surface with
the cable strain release facing downward.