Host List: Two hostnames may be configured for this test. Hostnames can be specified
in the form of domain names or IP addresses. If the first hostname fails to get a reply, the
same test is attempted for the second hostname. If no reply is received for either
hostname, the test fails. The primary and secondary DNS names should be fully
qualified domain names. Note that the reverse lookup of an IP address is possible, but
that is usually unlikely to succeed in returning a name. Still, such a reverse lookup can
be used to demonstrate the integrity of the mobile connection.
– Primary Test Hostname: The first hostname to look up.
– Secondary Test Hostname: The second hostname to look up (if the first hostname
fails).
TCP test port number: The TCP port number to connect to on the remote host. The
default is 80.
Test type: There are several tests available:
–Ping Test
– TCP Connection Test
– DNS Lookup Test
– iDigi Connection Test
For descriptions of these tests, see page 50.
Link failure action: The action to be performed when a link failure is detected:
– Reset modem: Reset the cellular modem in the ConnectPort X2e ZB device.
– Reconnect interface: Reconnect the cellular interface.