Product manual
9XCite‐PKG‐R™RS‐232/485RFModem–ProductManualv2.1[2007.01.04]
©2007MaxStream,Inc. 31
SM (Sleep Mode) Parameter
<Non-AT Settable Parameter: Sleep Mode (Low 
Power)> SM Parameter is used to adjust Sleep 
Mode settings. By default, Sleep Mode is disabled 
and the radio modem remains continually active. 
SM Parameter allows the radio modem to run in a 
lower-power state and be configured in one of 
eight settings. 
Cyclic Sleep settings wake the radio modem after 
the amount of time designated by SM Command. 
If the radio modem detects a wake-up initializer 
during the time it is awake, it will synchronize 
with the transmitting radio modem and start 
receiving data after the wake-up initializer runs 
its duration. Otherwise, it returns to Sleep Mode 
and continue to cycle in and out of sleep until the 
wake-up initializer is detected. If a Cyclic Sleep 
setting is chosen, the ST, LH and HT parameters 
must also be set as described in the "Sleep Mode" section of this manual.
ST (Time before Sleep) Parameter
<Non-AT Settable Parameter: Sleep Mode (Low Power)> ST Parameter sets the period of time (in 
tenths of seconds) in which the radio modem remains inactive before entering into Sleep Mode. 
For example, if the ST Parameter is set to 0x64 ("100" decimal), the radio modem will enter into 
Sleep Mode after 10 seconds of inactivity (no transmitting or receiving). This command can only 
be used if either Cyclic Sleep or Serial Port Sleep Mode settings have been selected using SM 
(Sleep Mode) Parameter.
Parameter Range: 0x10 - 0xFFFF [x 100 ms]
# of bytes returned: 2
Default Parameter Value: 0x64 ("100" decimal)
Related Parameters: SM (Sleep Mode), LH (Wake-up Initializer Timer), HT (Time before Wake-
up Initializer)
VR (Firmware Version) Command 
<AT Command: AT Command Options> Reads and returns the currently loaded firmware version 
of the XCite Radio Modem.
AT Command: VR
Parameter Range: 0 - 0xFFFF [Read-only]
# of bytes returned: 2
WR (Write) Command 
<AT Command: (Special)> WR Command writes all configurable parameters to non-volatile mem-
ory. Using WR Command saves parameters to the radio modem's persistent memory. (This means 
that the parameters remain in the radio modem's memory until explicitly overwritten by future 
uses of WR Command.)
AT Command: WR
Parameter Ranges: 0 - 8
Parameter Configuration
0No Sleep
1 Pin Sleep
2 Serial Port Sleep
3 Cyclic 0.5 seconds
4 Cyclic 1.0 seconds
5 Cyclic 2.0 seconds
6 Cyclic 4.0 seconds
7 Cyclic 8.0 seconds
8 Cyclic 16.0 seconds
Default Parameter Value: 0
Number of bytes returned: 1