User`s guide
Specifications
Chapter 13 Reference and Certifications 115
Specifications
Power Requirements
Product
Typical Power Consumption
DC Current @ 120 Vac (mA)
Max Power
Consumption
(watts)
Recommended Power
Supply Input Rating
(watts)
•PortServer TS
• PortServer TS MEI
• PortServer TS M MEI
• PortServer TS W MEI
• PortServer TS P MEI
4W (330mA @ 12 Vdc) 12W (1A @ 12Vdc) 42W (120V * 35A)
External power supply
provided with product
purchase
• PortServer TS 8 6W (500mA @ 12Vdc) 12W (1A @ 12Vdc) 42W (120V * 35A)
External power supply
provided with product
purchase
• PortServer TS 8 DC 6W (125mA @ 48Vdc) 12W (.25A @
48Vdc)
20W (.4A @ 48Vdc)
External power supply
provided with product
purchase
• PortServer TS 16 DC 10W (200mA @ 48Vdc) 20W (.4A @ 48Vdc) 25W (.45A @ 48Vdc)
• PortServer TS 8 MEI
• PortServer TS 16
• PortServer TS 16 MEI
10W (85mA @ 120Vdc) 20W (.17 A
@12Vdc)
96W (120V * 8A)
• PortServer TS 16 Rack DC 12W 2 (250mA @ 48Vdc) 29W (600mA @
48Vdc)
34W (700mA @
48Vdc)
• Digi One SP
• Digi One IA
• Digi One IAP
• Digi One IAP Haz
Device is intended to be powered by a listed LPS or Class II power supply
rated.
9-30 VDC (barrel connector), 0.37 A minimum or its equivalent.
• Digi One IAP
• PortServer TS P MEI
Power over Ethernet IEEE 802.3af:
IEEE 802.3af defines two types of power source equipment:
end-span and mid-span.
• End-span refers to an Ethernet switch with embedded
Power over Ethernet technology. These new switches
deliver data and power over the same wiring pairs -
transmission pairs 1/2 and 3/6.
Mid-span devices resemble patch panels. They are placed
between legacy switches and the powered devices. Each of
the mid-span ports has an RJ-45 data input and data/power
RJ-45 output connector. Mid-span devices tap the unused
wire pairs 4/5 and 7/8 to carry power, while data runs on the
other wire pairs.
Digi One IAP and PortServer TS P MEI and are mid-span and
end-span.
Typical: 4 watts
Max: 6 watts