User`s guide

Safety Statements
114 Chapter 13 Reference and Certifications
Class I Division 2, Groups A,B,C,D Hazardous Location
Applicable to these products:
Digi One IA
Digi One IAP
Digi One IAP Haz
PortServer TS 1 Haz MEI
PortServer TS 2 Haz MEI
PortServer TS 4 Haz ME
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and
D or Non-hazardous locations only.
Warning: Explosion Hazard – Substitution of components may impair
suitability for Class I, Division 2.
Warning: Explosion Hazard – Do not disconnect equipment unless power
has been switched off or the area is known to be non-hazardous.
Wiring Terminals for Digi One IA
Wiring terminals shall be plainly marked in the instruction manual delivered
with base product, or the device shall be provided with a wiring diagram to
indicate the proper connections. Wiring terminals shall also be marked with
the tightening torque in 5 lb. in. and “Use Copper Conductors Only.”