Chapter 4 IA Profiles and Procedures 53
3. Configure the port on the RealPort PC.
See the PC’s documentation for information on configuring serial ports.
Procedure: Configuring the Serial Port for RealPort
Use this topic for information on configuring the Digi One IAP.
1. Access the Digi One IAP configuration from a web browser by entering
the device’s IP address in the browser’s URL window.
2. Log on to the Digi One IAP as the root user as shown. The default
password is dbps.
3. Do one of the following:
4. Use the Add Digi RealPort wizard and the associated help text to
configure the RealPort driver with the IP address and TCP port number
used by the device server.
5. Follow the prompts to complete configuration of the RealPort driver.
Enabling Pass-Through Port
About these procedures
The Digi One IAP has a second DIP switch on the top of the device for
enabling the pass-through port. When the pass-through port DIP switch is
enabled (ON), the DIP switch bank for EIA-232/422/485 operates for the
screw terminal port only. The screw terminal port is port 1. The DB-9 serial
port operates as the second port supporting only EIA-232.
The following are the procedures to enable the pass-through port as well
as diagnostic and troubleshooting tips for using the pass-through port.
Procedure: Enabling the pass-through port
1. While the unit is off, slide the pass-through switch to ON.
2. Power up the unit.
3. Install RealPort from the Access Resource CD under Software.
Note: If the unit has already been configured and you are adding the pass-through
port, reboot the unit after enabling the pass-through port. If RealPort is
installed before the pass-through port is enabled, the driver must be
reinstalled. Configure the pass-through port as the Master port. See
"Configuring a Serial-Connected Master: Other IA Protocol" on page 51.
Running Diagnostics
The following diagrams are for the screw terminal loopback to be used
when testing two port functionality with the user diagnostics. When running
diagnostics, connect to the DB-9. When running user diagnostics in single
If the slave is using a supported
serial port protocol
If the slave is not using a supported
serial port protocol
Choose Port from the main menu.
Set the Device Profile to IA.
Click Apply and enter the protocol
information.
Choose Setup Wizards > RealPort.
Use the wizard to complete
configuration.