User`s guide

50 Chapter 4 IA Profiles and Procedures
Procedure
1. Access the web interface by entering the device server IP address in a
browser’s URL window.
2. Log in to the device server as root. The default password is dbps.
3. From the main menu, choose Setup Wizards > Industrial Protocols.
4. Choose the serial port protocol required by the slave that is connected
to the serial port.
5. Choose Slave as the device type.
Any number of network masters can communicate with the slave.
Configuring a Serial-Connected Master: Generic Procedure
About This Procedure
Use this procedure when a protocol master is connected to the serial port
of the device server. Use it except when the master requires TCP socket or
UDP socket communication. (See "Configuring a Serial-Connected Master:
TCP/UDP Sockets" on page 50 for information.)
Procedure
1. Access the web interface by entering the device server IP address in a
browser’s URL window.
2. Log in to the device server as root. The default password is dbps.
3. From the main menu, choose Setup Wizards > Industrial Protocols.
4. Choose the serial port protocol required by the master.
5. Choose Master as the Mode.
6. Configure up to 8 network slaves.
Configuring a Serial-Connected Master: TCP/UDP Sockets
About This Procedure
Use this procedure in the following situations:
When a protocol master using one of the supported serial port
protocols (Modbus ASCII, Modbus RTU, DF1 Full-Duplex, DF1 Half-
Duplex, FINS, Hostlink, CompoWay/F or a protocol that meets Digi’s
definition of a “user-defined” protocol) is connected to the serial port
When the master requires TCP or UDP sockets for network
communication
Procedure
1. Access the web interface by entering the device server IP address in a
browser’s URL window.
2. Log in to the device server as root. The default password is dbps.
3. From the main menu, choose Setup Wizards > Industrial Protocols.
4. Choose the serial port protocol required by the master.