User guide
664 User Guide and Technical Information
27
of a scene name, take number, and a fi le extension. For example, for scene S01, take T01, the polyphon-
ic fi le name and take name are both S01T01.wav.
scene number
take number
extension
S01T01.WAV
Folder Options
All fi les generated by the 664 can be saved to the Root directory, a Project Folder, a Daily (Roll) Folder,
or a Scene Folder (Files are saved to the Root directory by default). File organization is managed in
the Setup Menu option FILE STORAGE > FOLDER OPTIONS. Folder choices include TOP-LEVEL,
MID-LEVEL, and BOTTOM LEVEL FOLDERS. Folders are created when the record key is pressed.
This reduces the likelihood of empty folders.
Each folder resides in the folder one level below it. If the folder one level below the target folder is
set to <None>, the target folder will reside in the next level folder that is set to something other than
<None>.
Each folder level has a corresponding list of available names that can be edited manually by the user.
To add an entry to the list of folder names of any folder level:
1. Access Setup Menu option FILE STORAGE > FOLDER OPTIONS
2. Select desired folder level and press the Headphone Encoder.
3. Rotate the headphone Encoder to select <Add New Entry> then press the Headphone En-
coder. Use the on-screen keyboard to compose a name for the folder.
4. Slide the RTN Switch right to create the folder name and select it for this folder level.
Top-Level (Project) folder. The Top-Level folder can be named manually or set to <None>. The name
of the Top-Level folder will also be stored in the PROJECT fi eld of the iXML and bEXT chunks of all
subsequently recorded WAV fi les.
Mid-Level (Tape/Roll/Daily) folder. The Mid-Level folder can be named manually, by the date, or set
to <None>. When set to <Daily>, a folder will be automatically created and named according to the
date. Whenever a new day occurs, the 664 will prompt asking if the user would like to create a new
daily folder. With an example date of August 20th, 2012, the naming format of the daily folder would
be: 12Y08M20. The name of the Mid-Level folder will also be stored in the TAPE fi eld of the iXML and
bEXT chunks of all subsequently recorded WAV fi les.
Bo om-Level folder. The Bo om-Level folder can be named manually, by scene name, or set to
<None>. When set to <Scene>, a new folder will be created each time the scene name is changed.
Automatic File Splitting
A fi le on a FAT32 volume cannot exceed 4 GB. During recording, the 664 will split a take that exceeds
4 GB into multiple fi les. The split is sample-accurate, so fi les joined together in post-production will
be seamless. The maximum fi le size that the 664 creates can be adjusted from the Setup Menu option
FILE STORAGE > File Max Size. The following fi le size options are available:
• 4GB
• 2GB
• 1GB
• 640MB
• 512MB