User manual
Remote Control
R&S
®
RTO
751User Manual 1316.0827.02 ─ 06
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<Time> Range: 100E-12 to 10000
Increment: 100E-9
*RST: 100E-9
Default unit: s
TRIGger<m>:PARallel:PATTern:WIDTh:RANGe <WidthRangeMode>
Selects how the range of a pulse width is defined if TRIGger<m>:PARallel:
PATTern:MODE is set to WIDTh.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<WidthRangeMode> WITHin | OUTSide | SHORter | LONGer
WITHin
Triggers when the pattern comes false inside a given time range.
The time limit is defined by TRIGger<m>:PARallel:
PATTern:WIDTh[:WIDTh] and TRIGger<m>:PARallel:
PATTern:WIDTh:DELTa (Width
±
Delta).
OUTSide
Triggers when the pattern comes false before or after the given
time range. The time limit definition is the same as for WITHin
range.
SHORter | LONGer
Triggers when the pattern comes false before or after the given
width has expired. Width is set with TRIGger<m>:PARallel:
PATTern:WIDTh[:WIDTh].
*RST:
WITHin
TRIGger<m>:PARallel:PATTern:WIDTh[:WIDTh] <Width>
The effect depend on the setting of the TRIGger<m>:PARallel:PATTern:WIDTh:
RANGecommand.
For the ranges SHOrter and LONGer, the width defines the maximum and minimum time
limit, respectively.
For the ranges WITHin and OUTSide, the width defines the center of a range which is
defined by the limits "±Delta".
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Command Reference