R&S
®
RTO
749User Manual 1316.0827.02 ─ 06
TRIGger<m>:PARallel:STATe:EXPRession[:DEFine] on page 744
TRIGger<m>:PARallel:STATe:CSOurce:EDGE.................................................................749
TRIGger<m>:PARallel:STATe:BIT<n>..............................................................................749
TRIGger<m>:PARallel:STATe:CSOurce:EDGE <Slope>
Sets the edge of the clock signal. The crossing of the clock edge and the logical threshold
defines the time at which the logical states and the bus value are analyzed.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<Slope> POSitive | NEGative | EITHer
*RST: POSitive
TRIGger<m>:PARallel:STATe:BIT<n> <Bit>
Sets the required state for each digital channel that is used in the bus.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
<n> 0..15
Number of the digital channel
Parameters:
<Bit> HIGH | LOW | DONTCARE
Bit value: 1, 0, or X
Pattern Trigger
TRIGger<m>:PARallel:PATTern:BIT<n> <Bit>
Sets the required state for each digital channel that is used in the bus.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
<n> 0..15
Number of the digital channel
Parameters:
<Bit> HIGH | LOW | DONTCARE
Bit value: 1, 0, or X