User manual
Remote Control
R&S
®
RTO
729User Manual 1316.0827.02 ─ 06
TRIGger<m>:FLXRay:DPOSition <DataPosition>
Sets the number of data bytes to be skipped after start of the payload segment
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<DataPosition> Range: 0 to 255
Increment: 1
*RST: 0
TRIGger<m>:
FLXRay:DPTO <DataPositionTo>
Defines the last byte of interest, if the position operator TRIGger<m>:FLXRay:
DPOPerator defines a range.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<DataPositionTo> Range: 0 to 255
Increment: 1
*RST: 0
TRIGger<m>:FLXRay:DCONdition <DataOperator>
Sets the operator to set a specific data pattern or a data pattern range.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<DataOperator> OFF | EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
OFF
The data position is not relevant for the trigger condition.
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one data position
to be set with TRIGger<m>:FLXRay:DMIN.
INRange | OORange
In range / Out of range: Set the minimum and maximum value of
the range with TRIGger<m>:FLXRay:DMIN and TRIGger<m>:
FLXRay:DMAX.
*RST:
EQUal
Command Reference