728User Manual 1316.0827.02 ─ 06
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<CycleCountTo> Range: 0 to 63
Increment: 1
*RST: 0
TRIGger<m>:FLXRay:CSTep <CycleCountStep>
Specifies a step to trigger on each n-th cycle inside the given range. This allows for
specific triggering if slot multiplexing is used.
The condition TRIGger<m>:FLXRay:CENable on page 727 must be set to INRange
or OORange.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<CycleCountStep> Range: 1 to 63
Increment: 1
*RST: 1
TRIGger<m>:FLXRay:DPOPerator <DataPosiOperator>
Sets the operator for the data position. You can defined an exact position, or a position
range.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<DataPosiOperator> OFF | EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
OFF
The data position is not relevant for the trigger condition.
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one data position
to be set with TRIGger<m>:FLXRay:DPOSition.
INRange | OORange
In range / Out of range: Set the minimum and maximum value of
the range with TRIGger<m>:FLXRay:DPOSition and
TRIGger<m>:FLXRay:DPTO.
*RST:
EQUal
Command Reference