User manual

Remote Control
R&S
®
RTO
726User Manual 1316.0827.02 ─ 06
TRIGger<m>:FLXRay:PCONdition <PLOperator>
Sets the operator for the payload length trigger setting. You can defined an exact value,
or a range.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<PLOperator> OFF | EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
OFF
The payload length is not relevant for the trigger condition.
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one payload
length to be set with TRIGger<m>:FLXRay:PMIN.
INRange | OORange
In range / Out of range: Set the minimum and maximum value of
the range with TRIGger<m>:FLXRay:PMIN and TRIGger<m>:
FLXRay:PMAX.
*RST:
OFF
TRIGger<m>:FLXRay:PMIN <PayloadLength>
Specifies a payload length - the number of words in the payload segment - or sets the
the start value of an payload length range. Information is transmitted in 2-byte words, so
the number of data bytes in the payload segment is twice the payload length.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<PayloadLength> Range: 0 to 127
Increment: 1
*RST: 0
TRIGger<m>:FLXRay:PMAX <PayloadLengthTo>
Sets the the end value of a payload length range if the condition TRIGger<m>:
FLXRay:PCONdition is set to INRange or OORange.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Command Reference