User manual
Remote Control
R&S
®
RTO
717User Manual 1316.0827.02 ─ 06
Firmware/Software: FW 1.35
BUS<m>:LIN:FRAMe<n>:TRANslation?
Returns the label of the specified frame if translation is enabled.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the frame, number of the frame in the current acquisition,
1...n.
Return values:
<Translation> String with the ID Name (label)
Example:
BUS:LIN:FRAMe2:TRANslation?
Response: Temperature
Usage: Query only
Firmware/Software: FW 1.35
16.2.14.7
FlexRay (Option R&S RTO-K4)
● FlexRay Configuration...........................................................................................717
● FlexRay Trigger.....................................................................................................722
● FlexRay Decoding Results....................................................................................732
● Translation............................................................................................................737
FlexRay Configuration
BUS<m>:FLXRay:SRCType............................................................................................717
BUS<m>:FLXRay:SOURce<n>.......................................................................................718
BUS<m>:FLXRay:THReshold<n>....................................................................................718
BUS<m>:FLXRay:THENable...........................................................................................719
BUS<m>:FLXRay:THData..............................................................................................719
BUS<m>:FLXRay:PRSingle............................................................................................719
BUS<m>:FLXRay:PRDiff................................................................................................720
BUS<m>:FLXRay:PRLogic.............................................................................................720
BUS<m>:FLXRay:POLarity.............................................................................................721
BUS<m>:FLXRay:BITRate..............................................................................................721
BUS<m>:FLXRay:CHTYpe.............................................................................................721
BUS<m>:FLXRay:SEHB.................................................................................................721
BUS<m>:FLXRay:SRCType <SourceType>
Sets the type of measurement.
Suffix:
<m>
.
1..4
Selects the serial bus.
Command Reference