User manual
Remote Control
R&S
®
RTO
702User Manual 1316.0827.02 ─ 06
BUS<m>:LIN:TECHnology <Technology>
Sets the threshold voltage as defined for various signal technologies.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<Technology> V15 | V25 | V35 | V6 | V9 | MAN
V15
1.5 Volt (TTL)
V25
2.5 Volt (CMOS 5.0 V)
V35 | V6 | V9
3.5 V (7 V supply), 6.0 V (12 V supply), 9.0 V (18 V supply) respec-
tively
MAN
Manual setting of user-defined values with BUS<m>:LIN:DATA:
THReshold.
*RST:
V35
Usage: SCPI confirmed
BUS<m>:LIN:BITRate <Bitrate>
Sets the number of transmitted bits per second.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<Bitrate> Range: 1000 to 20000
Increment: 1
*RST: 9600
Default unit: bps
BUS<m>:LIN:POLarity <Polarity>
Defines the idle state of the bus. The idle state is the rezessive state and corresponds to
a logic 1.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<Polarity> IDLLow | IDLHigh
*RST: IDLHigh
Command Reference