User manual

Remote Control
R&S
®
RTO
698User Manual 1316.0827.02 ─ 06
<n> *
Selects the frame.
Return values:
<DataLengthCode> Number of data bytes in decimal values.
Range: 0 to 15
Increment: 1
*RST: 0
Usage: Query only
BUS<m>:CAN:FRAMe<n>:IDTYpe?
Returns the identifier type of the selected frame, the identifier format of data and remote
frames.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the frame.
Return values:
<IdentifierType> ANY | B11 | B29
B11: standard format, 11 bit
B29: extended format, 29 bit
*RST: B11
Usage: Query only
BUS<m>:CAN:FRAMe<n>:IDValue?
Returns the identifier value of the selected frame.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the frame.
Return values:
<IdentifierValue>
To set the value format, use FORMat:BPATtern.
The values below range, increment and reset are decimal val-
ues.
Range: 0 to 536870911
Increment: 1
*RST: 0
Usage: Query only