BUS<m>:UART:BAUDrate <Bitrate>
Same as BUS<m>:UART:BITRate.
Suffix:
<m>
.
1..4
Parameters:
<Bitrate> Range: 300 to 20000000
Increment: 1
*RST: 9600
Default unit: bps
Usage: Asynchronous command
BUS<m>:UART:PARity <Parity>
Defines the optional parity bit that is used for error detection.
See also: "Parity" on page 281.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<Parity> NONE | ODD | EVEN | MARK | SPC | DC
MARK
The parity bit is always a logic 1.
SPC
SPaCe: The parity bit is always a logic 0.
DC
Don't Care: the parity is ignored.
*RST: NONE
Usage: Asynchronous command
BUS<m>:UART:BITime <InterframeTime>
Defines a timeout between a stop bit and the next start bit. The frame start is the first start
bit after the interframe time.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<InterframeTime> Range: 1E-6 to 1
Increment: 1
*RST: 1E-3
Default unit: s
Usage: Asynchronous command