User manual

Remote Control
R&S
®
RTO
670User Manual 1316.0827.02 ─ 06
TRIGger<m>:SPI:DPTO <DataPositionTo>
Defines the last bit or word of interest, if TRIGger<m>:SPI:DPOPerator is set to
INRange.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<DataPositionTo> Range: 0 to 4095 for triggering on one line (MISO or MOSI),
2047 for triggering on both lines.
Increment: 1
*RST: 0
TRIGger<m>:
SPI:FCONdition <DataOperator>
Selects the operator for the MISO and MOSI pattern.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<DataOperator> EQUal | NEQual
*RST: EQUal
Firmware/Software: V 1.25
TRIGger<m>:SPI:MISopattern <MISOPattern>
Specifies the pattern to be triggered on the MOSI line.
Suffix:
<m>
.
1..3
Event in a trigger sequence: 1 = A-event only
Parameters:
<MISOPattern>
Numeric or string pattern, see chapter 16.2.2.6, "Bit Pattern
Parameter", on page 421. The string parameter accepts the bit
value X (don't care).
Usage: Asynchronous command
TRIGger<m>:SPI:MOSipattern <MOSIPattern>
Specifies the pattern to be triggered on the MOSI line.
Command Reference