User manual

Remote Control
R&S
®
RTO
598User Manual 1316.0827.02 ─ 06
MTESt:REMove <MaskTestName>
Deletes the mask test definition with the specified name.
Setting parameters:
<MaskTestName>
Usage: Setting only
SCPI confirmed
MTESt[:STATe] <MaskTestName>,<State>
MTESt[:STATe]? <MaskTestName>
Activates and deactivates the mask test. If the acquisition is running, the test starts
immediately. Otherwise, the test starts when acquisition is started.
The testing is stopped when acquisition is stopped, also due to the MTESt:
ONViolation:STOP command, or if MASK[:STATe] is set to "OFF".
Parameters:
<State> ON | OFF
*RST: OFF
Parameters for setting and query:
<MaskTestName>
Usage: SCPI confirmed
MTESt:RST
Clears all totals and results in all "Mask Test" result boxes.
Usage:
Event
Firmware/Software: FW 1.35
MTESt:SOURce <MaskTestName>,<MaskTestSource>
MTESt:SOURce? <MaskTestName>
Selects the waveform to be tested against the mask. All channel waveforms can be tes-
ted.
Parameters:
<MaskTestSource> NONE | C1W1 | C1W2 | C1W3 | C2W1 | C2W2 | C2W3 | C3W1 |
C3W2 | C3W3 | C4W1 | C4W2 | C4W3
Waveform to be tested, see chapter 16.2.2.2, "Waveform Param-
eter", on page 419
*RST: NONE
Parameters for setting and query:
<MaskTestName> String containing the name of the mask test
Usage: SCPI confirmed
Command Reference