User manual
Remote Control
R&S
®
RTO
574User Manual 1316.0827.02 ─ 06
16.2.9.12 Event Actions
MEASurement<m>:ONViolation:BEEP.............................................................................574
MEASurement<m>:ONViolation:ACQStop........................................................................574
MEASurement<m>:ONViolation:PRINt.............................................................................574
MEASurement<m>:ONViolation:WFMSave.......................................................................575
MEASurement<m>:ONViolation:BEEP <Beep>
Generates a beep sound for the specified event.
Suffix:
<m>
.
1..9
See "Measurement selection: MEASurement<m>" on page 522.
Parameters:
<Beep> NOACtion | SUCCess | VIOLation
See chapter 16.2.2.5, "Event Parameter", on page 421
*RST: NOACtion
Usage: SCPI confirmed
MEASurement<m>:ONViolation:ACQStop <StopAcq>
Stops data acquisition for the specified event.
Suffix:
<m>
.
1..9
See "Measurement selection: MEASurement<m>" on page 522.
Parameters:
<StopAcq> NOACtion | VIOLation
See chapter 16.2.2.5, "Event Parameter", on page 421
*RST: NOACtion
Usage: SCPI confirmed
MEASurement<m>:ONViolation:PRINt <Print>
Prints a screenshot including the measurement results to the printer defined using
SYSTem:COMMunicate:PRINter:SELect<1..2> for the specified event.
Suffix:
<m>
.
1..9
See "Measurement selection: MEASurement<m>" on page 522.
Parameters:
<Print> NOACtion | SUCCess | VIOLation
See chapter 16.2.2.5, "Event Parameter", on page 421
*RST: NOACtion
Usage: SCPI confirmed
Command Reference