User manual
Remote Control
R&S
®
RTO
544User Manual 1316.0827.02 ─ 06
Meas.
suffix
<MeasType>
parameter value
Meas. type Description/Result
36 SHR Setup/Hold ratio Setup/Hold ratio measurement. Setup/Hold ratio is the
ratio of the setup time to the sum of hold and setup time:
T
Setup
/
(T
Setup
+
T
Hold
)
Used as setting to activate the Setup/Hold ratio measure-
ment with MEASurement<m>:MAIN on page 524 and
MEASurement<m>:ADDitional on page 525
Used also in queries with MEASurement<m>:ARES
on page 570 and MEASurement<n>:RESult:.. com-
mands.
37 PROBemeter Trig. ProbeMeter DC voltage measured by the connected active R&S probe
MEASurement<m>:ENVSelect........................................................................................544
MEASurement<m>:DETThreshold...................................................................................545
MEASurement<m>:AMPTime:ALEVel..............................................................................545
MEASurement<m>:AMPTime:PSLope.............................................................................545
MEASurement<m>:AMPTime:DELay<n>:DIRection..........................................................545
MEASurement<m>:AMPTime:DELay<n>:ECOunt.............................................................546
MEASurement<m>:AMPTime:DELay<n>:LSELect............................................................546
MEASurement<m>:AMPTime:DELay<n>:SLOPe..............................................................546
MEASurement<m>:AMPTime:PTCount............................................................................547
MEASurement<m>:AMPTime:ESLope.............................................................................547
MEASurement<m>:AMPTime:CSLope.............................................................................547
MEASurement<m>:AMPTime:CLCK<n>:LSELect.............................................................548
MEASurement<m>:AMPTime:DATA<n>:LSELect.............................................................548
MEASurement<m>:AMPTime:LCHeck<n>:VALid..............................................................548
MEASurement<m>:AMPTime:LCHeck<n>:LOWer:LIMit.....................................................549
MEASurement<m>:AMPTime:LCHeck<n>:UPPer:LIMit.....................................................549
MEASurement<m>:AMPTime:LCHeck<n>:LOWer:MARGin...............................................549
MEASurement<m>:AMPTime:LCHeck<n>:UPPer:MARGin................................................549
MEASurement<m>:ENVSelect <EnvelopeCurve>
The command is only relevant for measurements on envelope waveforms. It selects the
envelope to be used for measurement.
Suffix:
<m>
.
1..9
See "Measurement selection: MEASurement<m>" on page 522.
Parameters:
<EnvelopeCurve> MIN | MAX | BOTH
MIN: measures on the lower envelope
MAX: measures on the upper envelope
BOTH: the envelope is ignored and the waveform measured as
usual
*RST: BOTH
Firmware/Software: V 1.25
Command Reference