User manual
Remote Control
R&S
®
RTO
533User Manual 1316.0827.02 ─ 06
Example:
REFLevel2:ABSolute:HIGH 0.015
Sets the high signal level for Channel1/Waveform1 to 15 mV.
C1W1 corresponds to suffix number 2.
Usage: SCPI confirmed
REFLevel<m>:ABSolute:LOW <SignalLow>
The signal value that represents a low level.
Suffix:
<m>
.
2...21
Source waveform, see chapter 16.2.2.1, "Waveform Suf-
fix", on page 419.
Parameters:
<SignalLow> Range: -100E+24 to 100E+24
Increment: 1E-3
*RST: 0
Default unit: V
Example:
REFLevel2:ABSolute:Low 0.0015
Sets the low signal level for Channel1/Waveform1 to 1.5 mV.
C1W1 corresponds to suffix number 2.
Usage: SCPI confirmed
REFLevel<m>:ABSolute:TDIStance <TopDistance>
The distance between the high signal level and the upper reference level.
Suffix:
<m>
.
2...21
Source waveform, see chapter 16.2.2.1, "Waveform Suf-
fix", on page 419.
Parameters:
<TopDistance> Range: 0 to 100E+24
Increment: 1E-3
*RST: 0
Default unit: V
Example:
REFLevel2:ABSolute:TDIStance 0.0002
Sets the top distance for Channel1/Waveform1 to 0.2 mV. C1W1
corresponds to suffix number 2.
See also: example "Manual reference level definition using abso-
lute values" on page 527
Usage: SCPI confirmed
REFLevel<m>:ABSolute:BDIStance <BottomDistance>
The distance between the lower reference level and the low signal value.
Command Reference