User manual

Remote Control
R&S
®
RTO
529User Manual 1316.0827.02 ─ 06
Parameters:
<LevelDetection> AUTO | MANual
*RST: AUTO
Example:
REFLevel2:LDETection MANual
Sets manual level configuration for Channel1/Waveform1. C1W1
corresponds to suffix number 2.
See also: "Programming Examples" on page 527
REFLevel<m>:RELative:MODE <RelativeLevels>
The lower, middle and upper reference levels, defined as percentages of the high signal
level.
Suffix:
<m>
.
2...21
Source waveform, see chapter 16.2.2.1, "Waveform Suf-
fix", on page 419.
Parameters:
<RelativeLevels> FIVE | TEN | TWENty | USER
FIVE
5/50/95
TEN
10/50/90
TWENty
20/50/80
USER
Set the reference levels to individual values with
REFLevel<m>:RELative:LOWer, REFLevel<m>:
RELative:MIDDle, and REFLevel<m>:RELative:UPPer.
*RST:
TEN
Example:
REFL2:REL:MODE FIVE
Reference levels for Channel1/Waveform1: Lower reference level
= 5% of high signal level, middle reference level = 50% of high
signal level, upper reference level = 95% of high signal level
See also: example "Manual reference level definition using relative
values" on page 528
Usage: SCPI confirmed
REFLevel<m>:USRLevel <UserLevel>
Defines whether the user-defined signal levels or user-defined reference levels are used
for the measurements.
Command Reference