User manual

Remote Control
R&S
®
RTO
523User Manual 1316.0827.02 ─ 06
Limit check............................................................................................................565
Statistics and Long-term Measurements...............................................................566
Results..................................................................................................................570
Gating....................................................................................................................572
Event Actions........................................................................................................574
16.2.9.1 General Settings
MEASurement<m>[:ENABle]...........................................................................................523
MEASurement<m>:SOURce...........................................................................................523
MEASurement<m>:CATegory.........................................................................................524
MEASurement<m>:MAIN................................................................................................524
MEASurement<m>:ADDitional.........................................................................................525
MEASurement<m>:AON.................................................................................................526
MEASurement<m>:AOFF...............................................................................................526
MEASurement<m>:CLEar...............................................................................................526
MEASurement<m>:MULTiple..........................................................................................527
MEASurement<m>:MNOMeas........................................................................................527
MEASurement<m>[:ENABle] <State>
Switches the indicated measurement on or off.
Suffix:
<m>
.
1..9
See "Measurement selection: MEASurement<m>" on page 522.
Parameters:
<State> ON | OFF
*RST: OFF
MEASurement<m>:SOURce <SignalSource>, [<SignalSource2>]
Defines the source of the measurement. The source can be any input signal, math or
reference waveform. Depending on the selected source, only suitable measurement
types are available.
Suffix:
<m>
.
1..9
See "Measurement selection: MEASurement<m>" on page 522.
Parameters:
<SignalSource> NONE | C1W1 | C1W2 | C1W3 | C2W1 | C2W2 | C2W3 | C3W1 |
C3W2 | C3W3 | C4W1 | C4W2 | C4W3 | M1 | M2 | M3 | M4 | R1 |
R2 | R3 | R4 | D0 | D1 | D2 | D3 | D4 | D5 | D6 | D7 | D8 | D9 | D10 |
D11 | D12 | D13 | D14 | D15
Source of the measurement, see chapter 16.2.2.2, "Waveform
Parameter", on page 419
Digital channels are provided with option R&S RTO-B1.
*RST: NONE
Command Reference