User manual

Remote Control
R&S
®
RTO
455User Manual 1316.0827.02 ─ 06
Parameters:
<Type> EDGE | GLITch | WIDTh | RUNT | WINDow | TIMeout | INTerval |
SLEWrate | DATatoclock | STATe | PATTern | ANEDge |
SERPattern
Most of the type values are self-explanatory.
DATatoclock
Data2Clock: analyzes the relative timimg between a data signal
and the synchronous clock signal.
ANEDge
Analog Edge trigger which uses the analog trigger signal while the
Edge trigger uses the digitized trigger signal.
SERPattern
Serial Pattern for signals with serial data patterns in relation to a
clock signal.
*RST:
EDGE
TRIGger<m>:
LEVel<n>[:VALue] <Level>
Sets the trigger level for the specified event and source.
Suffix:
<m>
.
1..3
Indicates the event in a trigger sequence: 1 = A-event, 2 = B-event,
3 = R-event.
<n> 1..9
Indicates the trigger source:
1...4 = channel 1...4
5 = External Trigger Input on the rear panel for analog signals
6...9 = not available
Parameters:
<Level> Voltage for the trigger level.
Range: -10 to 10
Increment: 1E-3
*RST: 0
Default unit: V
TRIGger<m>:FINDlevel
Sets the trigger level automatically. The command is not available for an external trigger
source.
Suffix:
<m>
.
1..3
Indicates the event in a trigger sequence: 1 = A-event, 2 = B-event,
3 = R-event.
Usage: Event
Asynchronous command
Command Reference