User manual

Protocol Analysis
R&S
®
RTO
316User Manual 1316.0827.02 ─ 06
Fig. 10-16: FlexRay - decoded dynamic slot and results table
Table 10-6: Content of the "Decode results" table
Column Description
State Overall state of the frame.
"Insuffcient waveform length" indicates that the frame is not completely contained in
the acquisition. Change the horizontal scale, or move the reference point to the left
to get a longer acquisition.
Frame start Time of frame start
Type Frame type: Frame of the static segment, frame of the dynamic segment, wakeup
frame, symbol in the frame
Flags State of indicator bits
Payload length Number of data words in the payload segment.
Frame ID Value of the frame ID (slot number)
HCRC Value of the header CRC
FCRC Value of the frame CRC
Cycle count Number of the current FlexRay cycle
Values Value of the data bytes. The data format is selected below the table. Wakeup and
symbol frames frames do not transmit data, therefore "- - -" is displayed.
SCPI commands:
BUS<m>:FLXRay:FCOunt on page 732
FlexRay (Option R&S
RTO-K4)