User manual
Protocol Analysis
R&S
®
RTO
311User Manual 1316.0827.02 ─ 06
"Error condi-
tion"
Triggers on one or more errors that are detected in the decoded data,
see "Error conditions" on page 314.
SCPI command:
TRIGger<m>:FLXRay:TYPE on page 722
Indicator bits
Triggers on one or more indicator bits at the beginning of the header segment. Each bit
can be set to 0, 1, or X (don't care).
Trigger type: "Identifier + data"
Payload Trailer
Cycle
count
Header
CRC
Pay-
load
length
Frame ID
Reserved bit
Payload preamble
Null frame
Synch frame
Startup frame
Indicators
5 bits
"Payload pre-
amble"
Indicates a Network Management Vector in the payload segment. The
NMV allows the host processor to send data directly, without processing
by the communication controller.
"Null frame"
Indicates a frame without usable data.
"Sync frame"
Indicates that the frame is used for synchronization of the FlexRay sys-
tem. Only sync nodes can send this frame type.
"Startup frame"
Indicates a startup frame used for startup of the network. Only specific
start nodes can send this frame type.
SCPI command:
TRIGger<m>:FLXRay:PLPReamble on page 723
TRIGger<m>:FLXRay:NUFRame on page 724
TRIGger<m>:FLXRay:SYFRame on page 724
TRIGger<m>:FLXRay:STFRame on page 724
Frame ID (min/max)
The frame ID contains the number of the slot in which the frame is transmitted. Each
frame ID occurs only once during a FlexRay cycle.
Payload
Trailer
Cycle
count
Header CRC
Payload
length
Frame ID
Indica-
tors
5 bits 11 bits 11 bits7 bits 6 bits
To trigger on a frame ID, you have to define a condition and one or two identifier patterns.
The second identifier pattern is required to specify a range with conditions "In range" and
"Out of range". In binary format, use the following characters: 1; 0; or X (any bit). The use
of X is restricted to the conditions "Equal" and "Not equal". If the identifier is not relevant
for the trigger setup, set it to "Off".
FlexRay (Option R&S