User manual
Protocol Analysis
R&S
®
RTO
299User Manual 1316.0827.02 ─ 06
To select a bit rate from list of predefined values, tap the icon beside the "Bit rate" field.
To enter a specific value, open the keypad. The list of predefined values is also available
in the keypad.
If the "LIN standard" is "J2602", the bit rate is 10417 kbit/s and cannot be changed.
SCPI command:
BUS<m>:LIN:BITRate on page 702
LIN standard
Selects the version of the LIN standard that is used in the DUT. The setting mainly defines
the checksum version used during decoding.
The most common version is LIN 2.x. For mixed networks, or if the standard is unknown,
set the LIN standard to "Auto".
SCPI command:
BUS<m>:LIN:STANdard on page 703
Polarity
Defines the idle state of the bus. The idle state is the rezessive state and corresponds to
a logic 1.
SCPI command:
BUS<m>:LIN:POLarity on page 702
10.6.2.2 LIN Trigger
The "Events" tab of the "Trigger" dialog box provides the trigger settings for the configured
serial buses.
LIN (Option R&S RTO-K3)